Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

REACH Testing Methods: SVHC Screening and Restricted Substance Analysis Explained

REACH testing methods are the analytical procedures used to verify that products placed on the European Union market comply with Regulation (EC) No 1907/2006, including screening for Substances of Very High Concern (SVHC) and Annex XVII restricted substances. This technical guide explains the standard laboratory techniques—from ICP-OES and GC-MS to wet-chemical migration testing—that accredited third-party laboratories apply to polymers, textiles, metals, and electronic components. Read on to learn how REACH testing works, which sample types and testing items are covered, and how manufacturers can maintain continuous compliance.

Technical Overview

REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) is Regulation (EC) No 1907/2006 of the European Union and one of the most comprehensive chemicals legislations in the world. While registration duties primarily target manufacturers and importers of chemical substances and mixtures, producers and importers of finished articles must ensure that their products do not contain Substances of Very High Concern (SVHC) above 0.1% weight-by-weight (w/w) or substances whose use is restricted under Annex XVII. REACH testing methods are the analytical procedures used by accredited third-party laboratories to verify this compliance through chemical analysis of materials and components.

The regulatory framework relevant to article testing consists of three pillars:

  • Candidate List of SVHCs: substances identified by the European Chemicals Agency (ECHA) as carcinogenic, mutagenic, reprotoxic, persistent, bioaccumulative, toxic, or of equivalent concern. If an SVHC is present above 0.1% w/w, suppliers must communicate information down the supply chain, and importers may be obliged to notify ECHA or submit data to the SCIP database under the Waste Framework Directive.
  • Annex XIV (Authorisation List): SVHCs whose use requires explicit authorisation after a specified sunset date.
  • Annex XVII (Restrictions): substance-specific limits and bans applicable to consumer articles, such as nickel release, azo colorants, cadmium, lead, phthalates, PAHs, and organotin compounds.

ECHA updates the Candidate List approximately twice per year, and it now contains well over 240 entries. Because the list evolves continuously, REACH testing is not a one-time event but an ongoing verification program integrated into product compliance management.

Testing Samples

REACH testing is performed on homogeneous materials, meaning each analyzed portion must consist of a single material that cannot be mechanically disjointed into different components. Typical sample categories include:

Polymers and Plastics

PVC, polyolefins, ABS, elastomers, and rubber compounds are screened for phthalate plasticizers, halogenated flame retardants, short-chain chlorinated paraffins, PAHs in rubber goods, and SVHC monomers or additives. Samples are usually cut, cryo-milled, and homogenized before extraction.

Textiles and Leather

Natural and synthetic fibers, coated fabrics, and leather are tested for restricted azo dyes, formaldehyde, pentachlorophenol, chromium VI in leather, perfluorinated compounds, and chlorinated paraffins. Dyed and printed areas are analyzed separately from undyed base materials.

Metals and Coated Articles

Metal alloys, coatings, platings, and solder are analyzed for lead, cadmium, and nickel release. Conversion coatings on zinc and aluminum surfaces are specifically evaluated for hexavalent chromium.

Electrical and Electronic Products

Cables, housings, printed circuit boards, connectors, and plastic components are tested for SVHC plasticizers, flame retardants, and regulated elements, following the homogeneous-material dissection principles established in the EN IEC 62321 series.

Coatings, Paints, Inks, and Adhesives

Liquid and cured formulations are assessed for SVHC solvents, bisphenols, phthalates, and heavy-metal pigments.

Toys and Childcare Articles

These products attract heightened scrutiny and are additionally evaluated for element migration using methods aligned with EN 71-3, alongside standard SVHC screening.

Testing Items

Testing scopes generally fall into two categories: full SVHC screening against the current Candidate List, and targeted quantitative testing for Annex XVII restricted substances. Common testing items include:

  • SVHC full screening: typically more than 240 substances covering phthalates, bisphenols, phenolic compounds, flame retardants, solvent stabilizers, and metal compounds.
  • Phthalates: DEHP, DBP, BBP, DIBP, DINP, DIDP, DNOP, and related esters used as plasticizers.
  • Heavy metals: lead, cadmium, mercury, total chromium, hexavalent chromium, arsenic, and nickel release from articles in prolonged skin contact.
  • Azo colorants: reductive cleavage to restricted carcinogenic aromatic amines in textiles and leather.
  • Polycyclic aromatic hydrocarbons (PAHs): the REACH-relevant PAHs, including benzo[a]pyrene, in rubber and plastic components touching the skin.
  • Chlorinated paraffins: short-chain and medium-chain chlorinated paraffins used as flame retardants and plasticizers.
  • Flame retardants: PBDEs, HBCDD, TBBPA, tris(2-chloroethyl) phosphate, and related halogenated compounds.
  • Organotin compounds: TBT, DBT, MBT, DOT, and TPhT in PVC, textiles, and silicone products.
  • Formaldehyde: free and released formaldehyde in textile and leather articles.
  • Perfluorinated compounds: PFOA, PFOS, and related PFAS used for water and grease repellency.
  • Dimethyl fumarate (DMF): anti-mold agent banned in articles contacting skin.

Testing Methods

REACH testing combines sample preparation, extraction or digestion, and instrument-based quantification. The choice of method depends on the analyte class, matrix, and whether total content or migration is regulated.

Sample Preparation and Homogenization

Articles are disassembled into homogeneous materials, which are then cut, ground, or cryogenically milled to increase surface area and ensure representative extraction. Particle size and homogeneity directly influence recovery and reproducibility.

Rapid Screening by XRF

X-ray fluorescence spectrometry provides fast, non-destructive screening for elemental contaminants such as lead, cadmium, mercury, bromine, and chlorine. Positive XRF results are confirmed using destructive elemental techniques.

Elemental Analysis by ICP-OES and ICP-MS

Metals are quantified after acid digestion, typically microwave-assisted, using inductively coupled plasma optical emission spectrometry (ICP-OES) or inductively coupled plasma mass spectrometry (ICP-MS). Established procedures include the digestion and measurement protocols in the EN IEC 62321 series for electronic assemblies and EN 1122 for cadmium in plastics. Detection limits in the low mg/kg range comfortably support the 0.1% w/w SVHC threshold and the stricter Annex XVII limits.

GC-MS Analysis of Semivolatile Organics

Gas chromatography–mass spectrometry is the workhorse for phthalates, PAHs, organotin compounds after derivatization, flame retardants, and chlorinated paraffins. Samples undergo solvent extraction with appropriate solvents, followed by GC-MS quantification against calibrated standards. Chlorinated paraffins in leather can be determined according to ISO 18219, and phthalates in childcare items according to EN 14372.

HPLC and LC-MS/MS Techniques

Azo dyes are analyzed after reductive cleavage in a citrate-buffered solution, with liberated aromatic amines quantified by HPLC-DAD or GC-MS in line with EN 14362-1 and EN 14362-3. Bisphenol A, phenolic SVHCs, and perfluorinated compounds are determined by HPLC with fluorescence or mass-spectrometric detection (LC-MS/MS), which offers high sensitivity and selectivity for polar, thermolabile analytes.

Migration and Release Testing

Where REACH regulates release rather than total content, simulative extraction methods are applied: nickel release is measured after one week in synthetic sweat according to EN 1811, with wear-and-corrosion pre-treatment of coated items per EN 12472; hexavalent chromium in leather is determined by colorimetric or chromatographic methods per EN ISO 17075-1; formaldehyde in textiles is quantified after water-bath extraction per EN ISO 14184-1; and element migration from toys follows EN 71-3 with gastric-intestine simulant solutions.

For SVHC screening, laboratories typically target a limit of quantification at or below 100 mg/kg (0.01% w/w), providing a tenfold safety margin against the 0.1% reporting threshold. Results are reported per homogeneous material with clear identification of the tested component.

Applications

REACH testing is applied across the product lifecycle wherever goods are manufactured for, or imported into, the European Economic Area. Key applications include:

  • EU market access: demonstrating that consumer products, electronics, toys, textiles, footwear, and jewelry meet SVHC and Annex XVII requirements before customs clearance and placement on the market.
  • Importer due diligence: providing the analytical evidence EU importers need to fulfill information and notification obligations toward ECHA and the SCIP database.
  • Supply chain communication: generating the substance data required for Article 33 SVHC information transfer along the supply chain to downstream users and consumers.
  • Material and supplier qualification: verifying incoming plastics, dyes, coatings, and chemicals during product development and vendor audits.
  • Ongoing quality control: periodic re-screening after each Candidate List update or material change, and root-cause investigation in case of market surveillance actions or recall claims.

FAQ

What is the difference between REACH SVHC testing and REACH registration?

REACH registration applies to companies that manufacture or import chemical substances in quantities above one tonne per year and involves dossier submission to ECHA. SVHC testing, by contrast, is chemical analysis of finished articles or components to verify whether listed substances exceed the 0.1% w/w threshold. Most product manufacturers and article importers only need testing and communication, not registration.

Is REACH testing legally mandatory?

There is no blanket legal obligation to test every article, but market surveillance authorities can demand evidence of compliance, and only analytical testing can conclusively demonstrate that SVHCs are absent or below thresholds. Importers who cannot supply valid data risk border rejection, withdrawal orders, and penalties under national enforcement laws.

How much sample is required and how long does testing take?

Typical requirements are 10–30 grams or 10–30 square centimeters per homogeneous material, depending on the testing scope. Standard turnaround for full SVHC screening is five to ten working days; targeted single-item tests are usually faster. Only one material of each type per product usually needs testing.

How often should SVHC screening be repeated?

The Candidate List is updated approximately twice per year. Best practice is to review test reports after every update, re-test when newly listed substances plausibly occur in the product, and re-verify whenever materials, formulations, or suppliers change.

How does REACH differ from RoHS?

RoHS restricts ten specific substance groups in electrical and electronic equipment with fixed concentration limits, whereas REACH covers all article categories, contains a much longer and growing substance list, and imposes communication and notification duties above the 0.1% w/w threshold. The two regulations are complementary, and electronic products are commonly tested against both.

What does a non-detect result mean?

A result below the limit of quantification indicates the substance was not present above the method sensitivity, typically 100 mg/kg or lower for SVHC screening. This supports a compliance conclusion well below the 0.1% threshold, provided the tested sample is representative and the report reflects the current Candidate List.